Sequence Generation
- In this example,
interlacedTransmission
- Interlaced Transmission is enabledpucch_ResourceCommon
- Common resource configurationintraSlotFreqHopping
- Enabling Intra Slot Frequency Hoppingpucch_GroupHopping
- Enabling Group Hopping
numBatches = 7 #Number of User Equipments
interlacedTransmission = True #Enabling/Disabling the Interlaced Transmission
pucch_ResourceCommon = True #Selecting the resource set
numberOfSymb = None #Number of Symbols
symbolIndex_start = None #Starting Symbol Index
initial_CyclicShift = None #Initial Cyclic Shift
indexPUCCH = 0 #Index of the resource set, if Common resource configuration is enabled
intraSlotFreqHopping = False #Enabling/Disabling the Intra Slot Frequency Hopping
nID = 658 #Hopping ID
pucch_GroupHopping = 'Enable' #Enabling/Disabling the Group or/and Sequence Hopping
slotNumber = 1 #Slot Number
m_CS = np.array([ 9, 9, 10, 4, 7, 10, 6]) #Cyclic Shift Offset based on the information content
numInterlacedRBs = 10 #Number of Interlaced ResourceBlocks
Format0_SeqGenobj = PUCCHFormat0Sequence(intraSlotFreqHopping, interlacedTransmission, pucch_ResourceCommon) #Sequence Generation Object
Format0_Seq = Format0_SeqGenobj(numBatches, m_CS, nID, slotNumber, pucch_GroupHopping, initial_CyclicShift, numberOfSymb, symbolIndex_start, indexPUCCH, numInterlacedRBs) #Generates the PUCCH Format0 Sequence
- The example below considers,
interlacedTransmission
- Interlaced Transmission is disabledpucch_ResourceCommon
- Dedicated resource configurationintraSlotFreqHopping
- Disabling Intra Slot Frequency Hoppingpucch_GroupHopping
- Disabling Group Hopping
numBatches = 2 #Number of User Equipments
interlacedTransmission = False #Enabling/Disabling the Interlaced Transmission
pucch_ResourceCommon = False #Selecting the resource set
numberOfSymb = 1 #Number of Symbols
start_SymbIndex = 5 #Starting Symbol Index
indexPUCCH = None #Index of the resource set, if Common resource configuration is enabled
initial_CyclicShift = 4 #Initial Cyclic Shift
intraSlotFreqHopping = False #Enabling/Disabling the Intra Slot Frequency Hopping
nID = 287 #Hopping ID
pucch_GroupHopping = 'Disable' #Enabling/Disabling the Group or/and Sequence Hopping
slotNumber = 8 #Slot Number
m_CS = np.array([0, 7]) #Cyclic Shift Offset based on the information content
numInterlacedRBs = None #Number of Interlaces
Format0_SeqGenobj = PUCCHFormat0Sequence(intraSlotFreqHopping, interlacedTransmission, pucch_ResourceCommon) #Sequence Generation Object
Format0_Seq = Format0_SeqGenobj(numBatches, m_CS, nID, slotNumber, pucch_GroupHopping, initial_CyclicShift, numberOfSymb, symbolIndex_start, indexPUCCH, numInterlacedRBs) #Generates the PUCCH Format0 Sequence
- In this example,
interlacedTransmission
- Interlaced Transmission is enabledpucch_ResourceCommon
- Dedicated resource configurationintraSlotFreqHopping
- Disabling Intra Slot Frequency Hoppingpucch_GroupHopping
- Disabling Group Hopping
numBatches = 1 #Number of User Equipments
interlacedTransmission = True #Enabling/Disabling the Interlaced Transmission
pucch_ResourceCommon = False #Selecting the resource set
numberOfSymb = 1 #Number of Symbols
start_SymbIndex = 5 #Starting Symbol Index
indexPUCCH = None #Index of the resource set, if Common resource configuration is enabled
initial_CyclicShift = 7 #Initial Cyclic Shift
intraSlotFreqHopping = False #Enabling/Disabling the Intra Slot Frequency Hopping
nID = 408 #Hopping ID
pucch_GroupHopping = 'Disable' #Enabling/Disabling the Group or/and Sequence Hopping
slotNumber = 2 #Slot Number
m_CS = np.array([10]) #Cyclic Shift Offset based on the information content
numInterlacedRBs = 11 #Number of Interlaced ResourceBlocks
Format0_SeqGenobj = PUCCHFormat0Sequence(intraSlotFreqHopping, interlacedTransmission, pucch_ResourceCommon) #Sequence Generation Object
Format0_Seq = Format0_SeqGenobj(numBatches, m_CS, nID, slotNumber, pucch_GroupHopping, initial_CyclicShift, numberOfSymb, symbolIndex_start, indexPUCCH, numInterlacedRBs) #Generates the PUCCH Format0 Sequence
- class toolkit5G.SequenceGeneration.PUCCHFormat0Sequence(intraSlotFreqHopping=False, interlacedTransmission=False, pucch_ResourceCommon=False, seqNumber=0, numRBs=1)[source]
PUCCH Format 0 Sequence is symbol and Interlaced Resource Block dependent
PUCCH Format0 uses Low PAPR Sequence Type 1 with group hopping
The number of Bandwidth Part(BWP) considered is 1
The maximum number of Physical Resource Blocks(PRBs) allocated is 1
The maximum number of symbols allocated is 2
If PUCCH Format 0 is used prior to the allocation of dedicated PUCCH resource, it avail the resource information from the common resource configuration provided by the System Information Block 1 based on the index provided
If PUCCH Format 0 uses common resource configuration for resource allocation, the number of symbols allocated for transmission is always 2 and so, the ‘Intra Slot Frequency Hopping’ is always enabled
But, if PUCCH Format 0 uses dedicated resource set for transmission, then the ‘Intra Slot Frequency Hopping’ can either be enabled or disabled. It can be enabled only if Number of symbols allocated is 2
The interlaced based transmission can either be enabled or disabled within a BWP. The number of Interlaced Resource Blocks can be either 10 or 11
There is always 1 sequence within each group and so, the same sequence will always be selected in case of PUCCH Format 0. And so, the Sequence number is always 0
The Sequence Length for PUCCH Format 0 is 12
- Parameters:
intraSlotFreqHopping (bool) – The parameter ‘intraSlotFreqHopping’ indicates whether the Intra Slot Frequency Hopping is enabled/disabled. By default it is disabled.
interlacedTransmission (bool) – The parameter ‘interlacedTransmission’ indicates whether Interlaced based transmission is either enabled or disabled. By default it is disabled.
pucch_ResourceCommon (bool) – The parameter ‘pucch_ResourceCommon’ indicates whether PUCCH Format 0 uses common resource configuration or dedicated resource set for resource allocation. By default it is set that PUCCH Format 0 is used after dedicated resource allocation.
seqNumber (int) – The parameter ‘seqNumber’ is the sequence number indicating the base sequence to be selected. In case of PUCCH Format 0, there is only 1 sequence within the group and the same sequence will be selected always from each group. And so, ‘seqNumber’ is initialised with 0.
numRBs (int) – The parameter ‘numRBs’ is the number of PRBs allocated and it is initialised with 1.
- Input:
numBatches (int) – The parameter ‘numBatches’ is the number of User Equipments. It can take any positive scalar or numpy integer.
m_CS (numpy array of integer(s)) – This parameter denotes the cyclic shift offset based on the information content. It can take numpy array containing positive integer value(s).
controlInfo (str) – This parameter interprets the control information carried. Valid control information that it can take is “1-HARQ”, “2-HARQ”, “SR”, “HARQ+SR”.
nID (int) – Hopping ID ranging from 0 to 1023. This takes integer.
slotNumber (int) – It is the slot number allocated. It takes the value (integer) beteen 0 and maximum slots within a frame.
pucch_GroupHopping (str) – This parameter defines whether group hopping and sequence hopping has been enabled. Possible input it can take is ‘neither’, ‘enable’, ‘disable’.
‘neither’ - The value of ‘neither’ is used to signal that there is no group hopping nor sequence hopping.
‘enable’ - The value of ‘enable’ is used to enable group hopping and disable sequence hopping.
‘disable’ - The value of ‘disable’ is used to disable group hopping and enable sequence hopping.
initial_CyclicShift (int) – The parameter ‘initial_CyclicShift’ denotes the Initial Cyclic Shift. It can take values between 0 and 11. The values should be an integer. It can be either provided by dedicated resource set or common resource configuration and so it is initialised with None
numberOfSymb (int) – The parameter ‘numberOfSymb’ is the number of Symbols allocated. Maximum of 2 symbols per slot can be allocated. It takes only positive scalar or numpy integer. It can be either provided by dedicated resource set or common resource configuration and so it is initialised with None
start_SymbIndex (int) – The parameter ‘symbolIndex_start’ indicates the starting symbol index. It can take a integer. Taking into consideration that maximum of 14 symbols within a slot, it can take values between 0 and 13. It can be either provided by dedicated resource set or common resource configuration and so it is initialised with None
indexPUCCH (int) – The parameter ‘indexPUCCH’ is the resource index to indicate the resource in case of resource allocation by common resource configuration. It can be either provided by dedicated resource set or common resource configuration and so it is initialised with None
numInterlacedRBs (int) – The parameter ‘numInterlacedRBs’ is the Number of Interlaced Resource Blocks. It can take positive integer value. It can be either provided by dedicated resource set or common resource configuration and so it is initialised with None
- Output:
numpy ndarray, np.complex – Array of dimension, […,
numInterlacedRBs
/numRBs
, 12 *numberOfSymb
]If interlaced based transmission is enabled,
numInterlacedRBs
number of sequences are generated. Else,numRBs
number of sequences are generated. And, 12 is the sequence length.- Raises:
TypeError –
If
pucch_GroupHopping
is not of data type stringIf
indexPUCCH
is not of type integerIf
numRBs
is not a integer typeIf
numberOfSymb
is not of type integerIf
numBatches
is an integerIf
seqNumber
is not of type scalar or numpy integerIf
initial_CyclicShift
is not a scalar or numpy integerIf
m_CS
is not a numpy array of integersIf
start_SymbIndex
is not a scalar or numpy integerIf
numInterlacedRBs
is not a scalar or numpy integerIf
nID
is not type scalar or numpy array of integerIf
slotNumber
is not type scalar or array of integerIf
controlInfo
is not a stringValueError
If
indexPUCCH
is not between 0 and 2If
numRBs
is not equal to 1If
numberOfSymb
is not between 1 and 14. Also, ifnumberOfSymb
plusstart_SymbIndex
> 14If
numBatches
is a positive valueIf
seqNumber
is not a non negative valueIf
initial_CyclicShift
is not between 0 and 11If
m_CS
is not ‘0’, ‘3’, ‘6’, ‘9’If
start_SymbIndex
is not between 0 and 13If
nID
is not between 0 and 1023If
slotNumber
is not between 0 and 10If
numInterlacedRBs
is not equal to 10 or 11If
pucch_GroupHopping
doesn’t contain valid informationIf
controlInfo
doesn’t contain valid information
- property controlInfo
Control information carried by Format0 on the uplink control channel
- property indexPUCCH
This parameter is used to select the resource from the common resource configuration provided by SIB1.
- property initial_CyclicShift
Initial Cyclic Shift. Takes values between 0 and 11
- property m_CS
Cyclic shift offset depending upon the information to be transmitted
- property nID
Hopping ID - Higher layer parameter. Takes any values between 0 and 1023
- property numBatches
Number of User Equipments - Batching
- property numInterlacedRBs
Number of Interlaced Resource Blocks allocated
- property numRBs
Number of Physical Resource Blocks allocated
- property numberOfSymb
Number of OFDM Symbols allocated. Maximum of 2 symbols can be allocated
- property pucch_GroupHopping
Group Hopping and Sequence Hopping Information
- property seqNumber
Sequence number within a group depending upon the sequence hopping
- property slotNumber
Slot Number withi a Radio frame consisting of 10 slots
- property start_SymbIndex
Starting Symbol Index within a slot consisting of 14 OFDM symbols
References
[1]. (3GPP TS 38.211 version 17.1.0 Release 17) 5G;NR;Physical channels and modulation ‘5.2.2 Low-PAPR sequence generation type 1’
[2]. (3GPP TS 38.211 version 17.1.0 Release 17) 5G;NR;Physical channels and modulation ‘6.3.2.3 PUCCH Format 0’
[3]. (3GPP TS 38.213 version 16.5.0 Release 16) 5G;NR;Physical layer procedures for control ‘ 9.2.1 PUCCH Resource Sets’
[4]. Book - 5G NR in Bullets, Edition 1